Flow variation can be estimated by measuring the pressure variations using the following equation:



dQ (%) = (d P (%)/n)





where n is the power law index of the resin being extruded. Understanding this equation helps one to realize the importance of main taining a uniform head pressure, if constant flow rate is important.



Note: This formula has been corrected from the misprint that occurred in the original newsletter.