Melt temperature Vol. 17 #2, July 1990



Melt Temperature

Meaningful melt temperature readings are difficult to obtain.



A reasonable indication of melt temperature with standard sheathed T/C's can only be seen if the adaptor where the melt T/C is located is set near actual melt temperature. This may require some adjustment while watching the melt temperature reading.